Enhance wind uplift resistance while using fewer plates and fasteners with Sika Roofing’s RhinoBond®¹ system. 

RhinoBond is an alternative attachment system for Sarnafil and Sikaplan roof membranes. The RhinoBond system eliminates membrane fastener penetration by welding the membrane directly to the specially coated plates used to secure the insulation or hardboard to the deck. The result is a roofing system that uses fewer plates and fasteners while enhancing the wind uplift resistance.

yes
RhinoBond Benefits
  • Quick and easy to install
  • No membrane fastener penetrations
  • Even load distribution
  • Enhanced wind uplift resistance
  • Reduces membrane “flutter”
  • Elimination of half sheets
  • Covered by system warranty
  • FM approval up to 210 PSF
Sika Sarnafil RhinoBond System Installation

Induction Welding

The RhinoBond system uses a patented stand-up induction welding machine to fuse the membrane to the plates. Simply place the machine above the plate, activate it for the required cycle (only a few seconds) and then place a RhinoBond weighted magnet on top of the plate for a minimum of 60 seconds to assure a strong bond. For a roof system requiring a 1-90 PSF rating, you will use 10 fewer fasteners and plates for every square installed when compared to a typical in-seam, mechanically-attached system using a 10-foot wide membrane fastened 12 inches on center.

Sika RhinoBond System

For All Substrates

The RhinoBond system is ideally suited for attachment to a structural metal roof deck (using the grid pattern) as well as when re-roofing a metal building (using the purlin attachment).

The RhinoBond system, when using the grid pattern, distributes the uplift load over a larger area than typical in-seam, linear fastening systems. This reduces the likelihood of point loading of the deck. It also facilitates flexibility when installing the roof membrane, as orientation of the deck is not an issue (fastener rows must be perpendicular to the steel ribs in spot attached). The grid pattern also minimizes sheet flutter.

With metal building re-roofing projects, typically the roof consists of a light gauge metal panel, which does not provide adequate fastener pullout values. The typical roofing option is to fasten the membrane into the structural purlins which are usually spaced at 5-foot centers. This application usually requires the use of a special width membrane, or causes substantial membrane waste. Using the RhinoBond plate system, the dimensions of the roof membrane are no longer an issue. You can install the RhinoBond plate and purlin fastener into the purlin at the rate required to meet the uplift force. The standard 10-foot wide membrane is then placed over the attached substrate and induction welded to the plates.

Experience the difference that RhinoBond can make in roof performance and your bottom line. Call your Sika Roofing regional technical sales person to schedule a demonstration.

¹ RhinoBond® is a registered trademark of OMG, Inc. and is patent protected.